Shipping throughout Russia and to other countries

Ventilation in the operating room
There is only one way to achieve a sterile atmosphere in the operating room – pushing out internal air masses with an influx of fresh air-conditioned air
The ISO 14644 series of standards, which has the general name "Clean rooms and related control environments", developed by the International Organization for Standardization (ISO), is a universally recognized document that establishes standards for ventilation of clean rooms, design, construction, equipment and certification, as well as dividing them into special cleanliness classes.

Operation of the ventilation system in the operating room
Diagram of the air circulation system in the operating room in accordance with generally accepted norms and standards. It includes a diffuser, air ducts, a heating panel and a single-channel device of variable volume.
When designing, increased attention is paid to the technology of supplying air flows to special-purpose facilities. For example, air circulation in clean rooms with a purity class from 1 to 6 is carried out by air distribution equipment from top to bottom, forming homogeneous and unidirectional air flows of low speed from 0.2 to 0.45 m/s.

In areas of a lower purity class, the formation of a non-unidirectional flow is allowed with the help of several ceiling diffusers.

Methods of air purification
There are two types of clean rooms. As a rule, they differ in the method of purification of air masses:
Rooms with turbulent ventilation.
Rooms with laminar, one-way flow.

The latter variety allows you to observe the cleanliness of the highest possible degree, due to the fact that the flow directed in one direction pushes the polluted air out of the right room faster and better.

Air purification in a turbulent way.
When the air flow is purified by the turbulent method, the flows processed with the help of filters are fed through ceiling distributors. When clean air enters the room, it combines with the already present air mass, in which there is a certain level of contamination, and dilutes it.
Through the air intake grilles located at the bottom of the walls, a part of the displaced air is brought out. During the day of operation of ventilation installed on this principle, it can displace the exhaust air up to 20 times.

If it is necessary to make the air in a clean room even more purified, a view with a flow directed in one direction is selected. The meaning of laminar ventilation is to equip efficient filter components to supply air flow.

Fresh air entering the room moves through it in one direction (from top to bottom), while dust microparticles are retained and removed through holes in the floor. Usually this process takes place at an air flow rate of up to 0.4 m/s.

Models: RV-AMS-11.33, RV-AMS-11.34, RV-AMS-11.35, RV-AMS-11.36, RV-AMS-11.33.1, RV-AMS-11.34.1, RV-AMS-11.35.1, RV-AMS-11.36.1, RV-AMS-11.37, RV-AMS-12.33, RV-AMS-12.34, RV-AMS-12.35, RV-AMS-12.36, RV-AMS-12.33.1, RV-AMS-12.34.1, RV-AMS-12.35.1, RV-AMS-12.36.1, RV-AMS-12.37, RV-AMS-11.30.1, RV-AMS-11.30.2, RV-AMS-11.30.3, RV-AMS-11.30.6, RV-AMS-11.30.7, RV-AMS-11.30.5, RV-AMS-11.30.8, RV-AMS-11.30.9, RV-AMS-12.30.1, RV-AMS-12.30.2, RV-AMS-12.30.3, RV-AMS-12.30.5, RV-AMS-12.30.6, RV-AMS-12.30.7, RV-AMS-12.30.8, RV-AMS-24, RV-AMS-23, RV-AMS-22, RV-AMS-L, RV-AMS-U.

DOCUMENTS

All AMS-MZMO products

The group «New Technologies» offers products from the plant AMS-MZMO: medical and industrial clean rooms, laboratory equipment, ventilation and air conditioning systems of clean rooms
  • Laboratory equipment AMS-MZMO
    Laboratory equipment
    SLSH, BVSH, etc.
  • Clean room ventilation systems AMS-MZMO
    Clean room ventilation systems
    RV-AMS and so on.
  • Clean room air conditioning systems AMS-MZMO
    Clean room air conditioning systems
    KC-AMS, AMS, etc.
  • Resuscitation units AMS-MZMO
    Resuscitation units
    UBL, BOV, etc.
  • Medical Consoles AMS-MZMO
    Medical Consoles
    KPM-AMS, KPM-VE, etc.
  • Air purification units AMS-MZMO
    Air purification units
    BOV et al .
  • Lamps and irradiators AMS-MZMO
    Lamps and irradiators
    SSG, SLG, etc.
  • Industrial incubators AMS-MZMO
    Industrial incubators
    AMS-P and others.
  • Medical clean rooms AMS-MZMO
    Medical clean rooms
    blocks, halls, etc.
  • Clean production facilities AMS-MZMO
    Clean production facilities
    pharmaceutical, etc.
  • Enclosing structures AMS-MZMO
    Enclosing structures
    windows, doors, etc.
  • Biosafety modules AMS-MZMO
    Biosafety modules
    MBB et al .
  • Modular buildings AMS-MZMO
    Modular buildings
    typical , etc .

About AMS-MZMO

AMC-MZMO (Miass) is well known in the field of medicine. The company produces a wide range of products for healthcare, industry, laboratories of various fields of activity.
  • the past

    Thanks to the enthusiasm with which the company's specialists took up the implementation of their ideas, unique developments of air purification units and sterile cabinets appeared for the first time in 1993.
  • INNOVATIONS

    Along with the serial production of ready-made and proven developments, the association continued to work at a rapid pace on the creation of the latest medical equipment.
  • present

    Over 25 years of hard and fruitful work, AMC-MZMO has turned from a tiny company around the corner into an extensive and modern production association with huge intellectual and technical potential.

Information Board AMS-MZMO

Learn more about our products AMS-MZMO.
  • Questionnaire factory AMC-MZMO
    Questionnaire

NEW TECHNOLOGIES GROUP

For sales and support please contact